Model | NS-A1 | NS-A1P |
Type | NPN | PNP |
Power | 12 to 24V DC, the pulsation (P-P) is maximum 10% |
Current / power | Max. 25mA |
Reaction time | Max. 1ms |
Temperature fluctuation | At the temperature of 23°c the detection distance is ±8%, ranging from 0 to 50X |
Sensitivity modulation | 25 ring knob regulator |
Operation mode | N.O./N.C. Selectable switch |
Timer function *1 | Optional 10ms delay / timer OFF |
Control output | NPN collector opens max. 100mA (40V), and the maximum residual voltage is 1V PNP collector opens max. 100mA(26.4V), and the maximum residual voltage is 1V |
Unconnected alarm output *2 | NPN collector opens max. 100mA (40V), and the maximum residual voltage is 1V PNP collector opens max. 100mA(26.4V), and the maximum residual voltage is 1V |
Circuit protection | Reverse current protection, output over voltage protection, and output surge protection. |
Ambient temperature | 0 to 50°c |
Relative humidity | 35 to 85% No condensation |
Weight | about 65g |